WP 3 – Condition monitoring and health assessment for large generators

Diagnosing generator faults you can barely tell apart, from data

Two faults that look almost identical

Large hydropower generators are custom-built, often decades old, and when they fail, it is usually the windings that go: a CIGRE survey of 17 utilities across five countries found that 57% of hydro-generator failures trace back to winding insulation damage, and stator faults account for roughly 60% of failures in heavy electrical machinery generally. Two of the most common underlying problems are an inter-turn short circuit (ITSC), where insulation breaks down and effectively shorts out part of a winding, and rotor eccentricity, where the rotor sits slightly off-centre in the stator bore. Both are dangerous if left undetected, since ITSC and eccentricity both feed into what is called unbalanced magnetic pull, which can escalate into serious mechanical damage.

Here is the frustrating part: at low severity, both faults nudge the generator’s vibration and electrical signals in almost the same way, at almost the same frequencies. And most industrial generators run with an automatic voltage regulator that actively corrects the output voltage, which erases the one signal (a change in the fundamental frequency component) that older diagnostic models relied on most. So the standard tools designed to catch these faults early are, in practice, being told everything is fine, right up until it very much is not.

Building a physics model sensitive enough to tell them apart

WP3’s core contribution is a sequence of increasingly refined physics-based models of exactly how these faults behave inside a generator, built specifically to solve this indistinguishability problem.

Early work in this line established winding-function models, first for demagnetization faults in permanent magnet machines, then extended to inter-turn short circuits, giving a mathematical way to predict the specific frequencies at which a fault should show up. That was followed by a vibration model that added the effect of varying load conditions, since a generator behaves differently at 30% load than at full load, and any diagnostic model that ignores this will misfire in the field.

The most complete result combines the Maxwell stress tensor with airgap flux density to model both the radial and tangential components of electromagnetic force under fault conditions, and it deliberately goes looking in a place earlier models did not: higher-order harmonics, rather than just the fundamental frequency. This turns out to be exactly the right place to look. Even when an AVR masks changes at the fundamental frequency, ITSC and eccentricity faults each leave a distinctive fingerprint in the higher spatial and temporal harmonics, one that a conventional analytical model tuned only to the fundamental would miss entirely. The model was checked two ways: against finite element simulations, and against real measurements from an in-house test rig built specifically to produce these faults on demand, in both healthy and faulty machines.

The real obstacle: finding data evidence for faulty cases

Physics models are only half the story, because the industry ultimately wants automated fault classification, and modern fault classifiers are built on machine learning, which needs data, ideally lots of it, from both healthy and faulty machines. Real hydropower generators are not going to be deliberately damaged to produce that training data, so fault datasets from actual failures are, by necessity, scarce.

The team’s answer was to use the analytical and numerical models as a source of realistic synthetic fault data, feeding model-generated signals in alongside a small number of real experimental fault samples to train supervised classifiers. The result, tested across support vector machines, linear discriminant analysis, kernel naive Bayes, k-nearest neighbours, and neural networks, was fault classification accuracy approaching 100%, achieved from a fault dataset too small to have supported reliable classification on its own.

A second strand of the work tackled a more specific practical constraint: many decades-old wound-field generators were never fitted with current sensors, and retrofitting them is invasive and costly. So the team asked whether faults could be classified from vibration data alone, measured with sensors that can simply be bolted on from outside the machine. Using a wavelet scattering transform combined with frequency features drawn from expert knowledge of the fault physics, the team successfully classified multiple winding fault types using only external vibration signals, a genuinely plug-and-play option for older machines that would otherwise be difficult to instrument.

A third strand applied the same diagnostic thinking to permanent magnet generators and motors, where an improved support vector classifier, tuned through kernel selection, reached 93.3% to 99.2% accuracy in telling apart demagnetization, inter-turn short circuits, and their combination, and a separate feature-selection study identified which statistical features (root-mean-square, standard deviation, and crest factor, specifically) best distinguish healthy machines from those with early-stage 2% and 5% short circuits.

Why this combination of physics and AI is the point

The throughline across all of this work is not any single result but the strategy: build a physics model precise enough to know what a fault should look like, use that model to manufacture the training data that real-world scarcity denies you, and only then hand the problem to machine learning. That approach is directly relevant to the wider Norwegian hydropower fleet, where generators are old, one-off in design, and have never failed in a way that produced a convenient labelled dataset. It also has a practical retrofit angle built in: some of this diagnostic capability works from vibration sensors alone, which matters enormously for the many hydropower generators still running without current sensors installed.

The publications behind this page

– T. Phuoc Nguyen, D-H. Ha, H. van Khang, K.G. Robbersmyr, “Harmonic-Based Analytical Model for Detecting Stator-Winding Short Circuit and Eccentricity Faults in Wound-Field Synchronous Generators,” *IEEE Access*, 2025.

– T.P. Nguyen, H. Van Khang, K.G. Robbersmyr, “Analytical Vibration Model of Stator Inter-Turn Short Circuit and Eccentricity in a Synchronous Generator at Different Loading Conditions,” *2025 IEEE WEMDCD*, Valletta, Malta.

– T.P. Nguyen, M.S. Mahmoud, V.K. Huynh, T-M-D. Tran, K.G. Robbersmyr, “Analytical Model-Augmented Supervised Machine Learning for Fault Diagnosis of WFSG with Limited Fault Samples,” *2025 ICEMS*.

– P. Nguyen, A. Islam, Z. Han, V.K. Huynh, A. Jha, K.G. Robbersmyr, “Multiple-winding Fault Classification in Wound Field Synchronous Generators Using Vibration Signals,” *2025 ICEMS*.

– T. Ahamed, T-P. Nguyen, H. Van Khang, K.G. Robbersmyr, “Improved Support Vector Classifier for Multiple Incipient Faults Diagnosis of a Permanent Magnet Synchronous Generator,” *2024 ICEM*.

– T. Ahamed, T.P. Nguyen, H.N.D. Nguyen, K. Huynh, S. Ghosh, “Enhancing Supervised-Learning Fault Classification of Permanent Magnet Synchronous Motors with Feature Selections,” *2024 ICCE*.

– T-P. Nguyen, H. Van Khang, K.G. Robbersmyr, “Winding Function Model for Detecting Demagnetization in Permanent Magnet Synchronous Machines,” *2024 ICCE*.

*Funded by PHMHydro (grant no. 333871, Research Council of Norway), a collaboration between University of Agder, NORCE Research AS, Å Energi AS, and Scanmatic AS.*